  • 01 ASSIGNMENT 1GROUP PRESENTATION SPREAD (SPACE LIGHT & VENTILATION) WEEKLY PROGRESS SUBMISSIONS
  • Page 301 ASSIGNMENT 1
  • SPACE, LIGHT & VENTILATIONBY-LAW 35 ACCESS FROM A STREET
  • BY-LAW 37PROJECTIONS OVER THE STREET AND OVER THE BUILDING LINE BY-LAW 39
  • BY-LAW 40AIR-WELLS Skylight to maximize use of natural light.
  • Page 73 This provision apply to building with mechanically ventilated or air conditioned. The provisions of these bylaws regarding natural ventilation and natural lighting shall not apply to lavatories, water closets, bathrooms, or corridors where permanent mechanical ventilation is provided for and maintained in accordance with the requirements of the Third Schedule to these bylaws.
  • DRAFT SUBMISSIONSPACE,LIGHT & VENTILATION
  • Page 9UBBL SPACE,LIGHT & VENTILATION
  • Page 1002 ASSIGNMENT 2
  • QUESTION 1QUESTION 1 INTERIOR DESIGN LICENSURE EXAMINATION
  • QUESTION 1QUESTION 1B QUESTION 1A
  • QUESTION 2QUESTION 2 (30 marks)
  • QUESTION 2QUESTION 28 QUESTION 2A
  • Page 1503 ASSIGNMENT 3
  • SIZE: 893SQFTRENTAL: RM3600/MONTH RENT RATE: RM 4.14 PSF (FLOOR)
  • SERVICE FRAMEWORKMARKETINGS STRATEGIES SPATIAL PLANNING & DESIGN CONSULTANCY (01
  • FUTURE PRACTICEDIGITAL & SMART DESIGN PRACTICE D
  • DRAFT SUBMISSIONSTAMPING MONTHLY EXPENDITURE
  • Page 2104 FINAL ASSIGNMENT
  • LIOW CHUN GUAN 0351029PROFESSIONAL PPRACTICE ARC 62604 FINAL PROJECT
  • SEVENTH SCHEDULE: MAXIMUM TRAVEL DISTANCEMEASUREMENT OF TRAVI UBBL 140(3G) THE MAXIMUM TRAVEL DISTANCES SHALL BE AS SPECIFIED IN THE SEV EXITS TO BE ACCESSIBLE AT ALL TIMES
  • EL DISTANCE TO EXITSTO EXITS AND DEAD END LIMITS ENTH SCHEDULE OF THESE BY LAWS EXIT ROUTE
  • DISABLED ACCESSIBILITYEXTINGUISHING SYSTEM FIRE ALARM
  • DRAFT SUBMISSIONDESIGN PROJECT ECHOES SACRED ECHOES IS AN IMMERSIVE CULTURAL EXPERIENCE CENTRE INSPIRED BY THE NINE EMPEROR GODS FESTIVAL AND THE PHILOSOPHY OF YIN AND YANG LOCATED IN ROYAL KLANG TOWN, THE PROJECT AIMS TO PRESERVE AND REINTERPRET LOCAL CULTURAL HERITAGE THROUGH INTERACTIVE EXHIBITIONS RITUAL-INSPIRED SPATIAL EXPERIENCES, TRADITIONAL CRAFT WORKSHOPS LEARNING SPACES AND COMMUNITY GATHERING AREAS. THE DESIGN CREATES A CONTEMPORARY PLATFORM FOR CULTURAL EDUCATION ENGAGEMENT AND CONTION WHILE STRENGTHENING APPRECIATION BETWE TRADITION
  • Page 2705 CONCLUSION
  • REFLECTIVE ESSAYTHIS PROFESSIONAL PRACTICE MODULE HAS PROVIDED ME WITH A DEEPER UNDERSTANDING OF THE RESPONSIBILITIES AND REALITIES OF BECOMING A PROFESSIONAL INTERIOR DESIGNER. THROUGHOUT THE SEMESTER, I GAINED VALUABLE KNOWLEDGE BEYOND THE DESIGN PROCESS, INCLUDING BUILDING BY-LAWS, PROFESSIONAL ETHICS, LICENSING REQUIREMENTS, CONSULTANCY PRACTICE, BUSINESS MANAGEMENT, AND STATUTORY SUBMISSION PROCEDURES. EACH ASSIGNMENT CHALLENGED ME TO THINK CRITICALLY, CONDUCT THOROUGH RESEARCH, AND APPLY INDUSTRY STANDARDS IN A PRACTICAL CONTEXT. WORKING ON THESE PROJECTS HAS STRENGTHENED MY ABILITY TO CONNECT CREATIVE DESIGN WITH PROFESSIONAL PRACTICE. I REALISED THAT SUCCESSFUL INTERIOR DESIGN IS NOT ONLY ABOUT CREATING
  • Page 2906 E-PORTFOLIO LINK
Text of this page
  • UBBL
  • SPACE,LIGHT & VENTILATION
  • Presented by Ricson Liow Chun Guan

Hello everyone, welcome to our presentation on BY-LAW 40

AIR-WELLS

Skylight to maximize use of natural light.

Turbo ventilators taking out of all hot air.

Opening facade keeps all activity areas ventilated through out the day.

provide natural light and improve ventilation within buildings.

BY-LAW 42

MINIMUM AREA OF ROOMS IN RESIDENTIAL BUILDINGS

A residential building's first livable room must be at least 11 square metres in size, the second must be at least 9.3 square are metres, and each additional room must be at least 6.5 square metres.

Every usable room in a residential construction

2 must be at least two metres wide.

A kitchen's width and area in a residential building must be at least 1.5 metres and 4.5 square metres respectively, must have enough width to provide usable space.

  • GROUP VIDEO
  • BY-LAW 39
  • NATURAL LIGHTING AND VENTILATION
  • BY-LAW 39
  • NATURAL LIGHTING AND VENTILATION
  • Natural lighting ventilation >15 square feet
  • Air passage
  • 10% clear floor area

Natural lighting ventilation >20% clear floor area

RESIDENTIAL & NON-RESIDENTIAL

Rooms must have natural lighting and ventilation through one or more windows with a total area of at least 10% of the clear floor area and openings capable of allowing free uninterrupted air passage of at least 5% of the floor area.

RESIDENTIAL & NON-RESIDENTIAL

Rooms must have natural lighting and ventilation through one or more windows with a total area of at least 10% of the clear floor area and openings capable of allowing free uninterrupted air passage of at least 5% of the floor area.

  • Air passage
  • >10% clear floor area
  • HOSPITAL

HOSPITAL

Rooms must have natural lighting and ventilation, including one or more windows with a clear floor area of at least 15 square feet and openings that allow for uninterrupted airflow of at least 10% of the floor space.

Rooms must have natural lighting and ventilation, including one or more windows with a clear floor area of at least 15 square feet and openings that allow for uninterrupted airflow of at least 10% of the floor space.

SCHOOL

Rooms must have natural lighting and ventilation, with windows covering at least 20% of the clear floor area and openings that allow for uninterrupted airflow of at least 10%.

Hospitals and schools require stricter ventilation standards enough daylight and airflow to maintain a healthy indoor environment.

  • BY-LAW 41
  • BY-LAW 40
  • AIR-WELLS
  • MECHANICAL VENTILATION AND AIR-CONDITIONING

Air-well 2 metres width

Windows and openings allowing uninterrupted air passage is not necessary if the rooms are equipped with mechanical ventilation or air-conditioning.

2a Minimum size of each air-well where provided in all buildings

BUILDINGS

MINIMUM SIZE

4 square metres

In case of air-conditioning failure there should be alternative ways to introduce fresh air into the room within half an hour.

  • 4 storeys
  • 4.5 square metres
  • 6 storeys
  • 5 square metres
  • 8 storeys
  • >8 storeys
  • 5.5 square metres

2b Minimum width of such air-wells in any direction shall be

2 metres.

may not require natural ventilation.

For bathrooms and lavatories, smaller air-wells are allowed due to lower

BY-LAW 43

MINIMUM DIMENSIONS OF LATRINES, WATER-CLOSETS AND BATHROOMS

BY-LAW 44

HEIGHT OF ROOMS IN RESIDENTIAL BUILDINGS, SHOPHOUSES, SCHOOLS, ETC

  • RESIDENTIAL BUILDINGS
  • MINIMUM SIZE
  • BUILDINGS
  • Water closet with pedestal-type
  • 1.5m x 0.75m
  • 2 Sloping ceilings in residential buildings:
  • BEDROOM 22.5M
  • Water doset other than pedestal-type
  • 1.25mx 0.75m
  • 1.5 square metres
  • (Width not 0.75 metres)

2a Living rooms and bedrooms, ≥ 2.5m

  • Bathrooms
  • LIVING
  • ROOM
  • BATHROOM
  • 2 square metres
  • (Width not 0.75 metres)
  • Bathrooms with close fittings
  • 22 M
  • 2b Kitchens, 2.25m

2c Bathrooms, water-closets, latrines, porches, balconies, verandahs, garages, 22m

KITCHEN

2.25M require different space requirements.

and the bathroom is not less than 2 meters.