EL DISTANCE TO EXITS
TO EXITS AND DEAD END LIMITS ENTH SCHEDULE OF THESE BY LAWS
EXIT ROUTE
LEGENDS
NO EXIT ROUTE MAY REDUCE IN WIDTH ALONG ITS PATH OF TRAVEL FROM THE STOREY EXIT TO THE FINAL EXIT.
Sprinkler Head
HORIZONTAL EXITS
WITH HORIZONTAL EXITS, STAIRCASES AND FINAL EXITS MUST ACCOMMODATE THE LARGER COMPARTMENT'S LOAD, BUT TOTAL EXIT WIDTH MUST BE AT LEAST HALF OF WHAT THE WHOLE BUILDING REQUIRES.
. EXIT DOORS MUST BE EASILY OPENED FROM INSIDE WITHOUT A KEY.
UBBL
Emergency Exit Sign
DOORS MUST AUTO-CLOSE AND RELEASE DURING POWER FAILURE OR FIRE ALARM.
ENCLOSED SPACE WITH EXHAUST FAN UNIVERSAL ACCESS DESIGN
Fire Door
Escape Route
SUSTAINABLE CONSTRUCTION REDUCE ENERGY USE BY HARNESSING DAYLIGHT.
FIRE ALARM SYSTEM AND EXTINGUISHMENT SYSTEM ALL BUILDINGS MUST HAVE A FIRE ALARM OR EXTINGUISHING SYSTEM (REFER TO THE TENTH SCHEDULE).
EMERGENCY EXIT SIGNS
EXIT SIGNS MUST BE CLEARLY VISIBLE, UNOBSTRUCTED, AND ILLUMINATED DURING OCCUPANCY. "KELUAR" SIGNS WITH ARROWS ARE NEEDED IF EXIT DIRECTION ISN'T CLEAR. MUST COMPLY WITH MS 2687 AND MS 619.
A HOSE REEL SYSTEM SHALL BE PROVIDED IN ACCORDANCE WITH THE TENTH SCHEDULE AND MS 1489.
FIRE ALARM SYSTEMS
A FIRE ALARM SYSTEM SHALL BE PROVIDED IN ACCORDANCE WITH THE TENTH SCHEDULE AND MS 1745.
A FIREFIGHTING LOBBY IS NEEDED IF THE TOP FLOOR EXCEEDS 18 M OR BASEMENT EXCEEDS 9 M FROM FIRE APPLIANCE ACCESS. IT MUST CONNECT TO THE STAIRCASE, FIRE LIFT, AND RISER WITHIN 45 M, UNLESS THE STAIRCASE IS PRESSURISED. FIRE LIFTS MUST OPEN TO THE LOBBY OR VIA A PROTECTED CORRIDOR, WITH MAXIMUM 60 M TRAVEL DISTANCE (5% IN OPEN PLANS). LIFTS TO UPPER FLOORS SHOULDN'T SERVE BASEMENTS UNLESS FOR LOW FIRE LOAD OR CAR PARK, WITH PROTECTED LOBBIES.
EXIT DOORS
UBBL
EXIT DOORS MUST BE EASILY OPENED FROM INSIDE WITHOUT A KEY.
DOORS MUST AUTO-CLOSE AND RELEASE DURING POWER FAILURE OR FIRE ALARM.
A SPRINKLER SYSTEM SHALL BE PROVIDED IN ACCORDANCE WITH THE TENTH SCHEDULE AND MS 1910.
A PORTABLE FIRE EXTINGUISHER SHALL BE PROVIDED IN ALL BUILDINGS IN ACCORDANCE WITH MS 1539.
UBBL
OCCUPANT(PAX)
DESIGN SYSTEMS TO PREVENT MOLD GROWTH MAINTAIN INDOOR HUMIDITY BELOW 70% RH. SELECT MATERIALS THAT PREVENT MOLD GROWTH AND CONTROL EXCESSIVE MOISTURE.
USE LOW VOC PAINTS, FLOORING AND ADHESIVES THROUGHOUT THE BUILDING.
PROVIDE RESPONSE MONITORING OF CO2 LEVELS TO MAINTAIN CO2 LEVEL ≤ 1,000 PPM.