DISABLED ACCESSIBILITY
PHYSICAL SUPPORT OF INFORMATION TACTILE FLOOR COVERINGS OR A RUNNER AS WELL AS TACTILE WALKING SURFACE INDICATOR (TWS) CAN HELP IN LOCATING ENTRANCE DOORS, COUNTERS ETC.
2- Manual electric fire alarm system 4 - Public address system
5 - Fireman intercom system and fire command centre
6- Automatic fire monitoring system
3. Two storeys and above (total floor
MS1184 (7.2)
A-Automatic Sprinkler System G-Hose Reel System area)
FLOOR FINISHES SHOULD HAVE NON-SLIP SURFACE WITH A TEXTURE TRAVERSABLE BY DISABLED PERSONS.
MS1184 (7.29)
2. Convention centre, community centre, private club, exhibition centre, museum or art gallery (total floor area) (c) Exceeding 2,000 square metres
WIDTH OF THE PATH
MS1184 THE UNOBSTRUCTED WIDTH OF THE PATH SHALL BE NOT LESS THAN 1800 MM FOR CONSTANT TWO-WAY TRAFFIC.
• COUNTER HEIGHT: 740-800 MM FROM FLOOR. CLEAR KNEE SPACE: MINIMUM 700 MM.
RECEPTION DESKS SHOULD ALLOW FRONT WHEELCHAIR ACCESS.
PART OF THE DESK SHOULD BE HIGHER (950-1100 MM) FOR STANDING USERS.
⚫ BUILDINGS MUST PROVIDE PWD ACCESS TO ENTER, EXIT, AND MOVE WITHIN, EXCEPT IN AREAS USED ONLY FOR MAINTENANCE OR INSPECTION.
⚫ MUST INCLUDE PWD-FRIENDLY FACILITIES, COMPLYING WITH MS 1183 & MS 1184.
MATERIAL MANUFACTURE & INGREDIENTS USAGE OF CERTIFIED ECO-FRIENDLY BUILDING INTERIOR MATERIALS FROM MANUFACTURERS COMMITTED RESPONSIBLE SOURCING AND MINIMAL CHEMICALS. (USE ≥5, USE ≥10 DIFFERENT.)
MATERIAL REUSE & SELECTION
MR1
INTERIOR MATERIALS MAKE UP ≥10% OF FIT-OUT COSTS. NON-STRUCTURAL MATERIAL COMPRISE ≥25% OF FIT-OUT COSTS.
USE LOCALLY SOURCED INTERIOR MATERIALS FOR ≥50% OF FIT-OUT COST.
PROMOTE MATERIALS WITH RECYCLED CONTENT IN BUILDING INTERIOR ≥30% PRODUCTS WITH RECYCLED CONTENT (FLOOR/CEILING/WALL/FIT-OFF).
⚫ MANOEUVRING SPACE IN FRONT OF DOORS: MINIMUM 1500 MM X 1500 MM.
FOR 180° WHEELCHAIR TURN: MINIMUM 1600 MM × 2150 MM.
EACH STRUCTURAL ELEMENT MUST BE CONSTRUCTED TO ACHIEVE THE FIRE RESISTANCE DURATION SPECIFIED IN THE NINTH SCHEDULE.
MATERIAL FOR CONSTRUCTION
A BUILDING PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM SHALL USE FIRE-RATED GLASS.
UBBL
WC COMPARTMENTS FOR AMBULANT DISABLED PEOPLE
WC COMPARTMENTS FOR AMBULANT DISABLED USERS MUST HAVE:
TOILET SEAT HEIGHT, DEPTH, AND WALL DISTANCE AS PER CLAUSE 25.6. CLEAR SPACE IN FRONT: MINIMUM 900 MM × 900 MM.
OUTWARD OPENING DOOR, MINIMUM WIDTH 800 MM (ESPECIALLY IN ELDERLY OR MEDICAL SETTINGS).
MS1184 (25.2
GRAB RAILS ON BOTH SIDES.
INDEPENDENT WATER SUPPLY AND FLOOR DRAIN WHERE REQUIRED.
HANDWASHING MUST BE COMMUNAL (IN SHARED WASHROOMS) OR PROVIDED NEARBY (IN STANDALONE UNITS).
NOT MORE THAN 4 M APART FROM EACH OTHER (REF: GUIDE TO FIRE PROTECTION IN MALAYSIA 11.2.7 SPRINKLER HEADS).
HOSE REEL SYSTEM COMPLY WITH MS 1447, PLACED WITHIN 30 M HOSE COVERAGE EACH HOSE REEL (REF: GUIDE TO FIRE PROTECTION IN MALAYSIA 7.7.2 HOSE REELS).
FLOOR & WALL SURFACES
WASHROOM
• RAMPS OFFER ACCESSIBLE ROUTES BETWEEN LEVEL CHANGES WITHOUT MECHANICAL DEVICES.
TACTILE WARNING INDICATORS MUST BE PLACED AT THE TOP AND BOTTOM OF RAMPS ON ACCESSIBLE PATHS.
INSTALL HIGH FREQUENCY BALLASTS IN FLUORESCENT LUMINAIRES FOR 100% OF INTERIOR SPACES.
EQ - INDOOR ENVIRONMENTAL QUALITY WE - WATER EFFICIENCY