  • ARC 62604BACHELOR OF ARTS (HONOURS) IN INTERIOR ARCHITECTURE PROFESSIONAL
  • 01 ASSIGNMENT 1GROUP PRESENTATION SPREAD (SPACE LIGHT & VENTILATION) WEEKLY PROGRESS SUBMISSIONS
  • Page 301 ASSIGNMENT 1
  • SPACE, LIGHT & VENTILATIONBY-LAW 35 ACCESS FROM A STREET
  • BY-LAW 37PROJECTIONS OVER THE STREET AND OVER THE BUILDING LINE BY-LAW 39
  • BY-LAW 40AIR-WELLS Skylight to maximize use of natural light.
  • Page 73 This provision apply to building with mechanically ventilated or air conditioned. The provisions of these bylaws regarding natural ventilation and natural lighting shall not apply to lavatories, water closets, bathrooms, or corridors where permanent mechanical ventilation is provided for and maintained in accordance with the requirements of the Third Schedule to these bylaws.
  • DRAFT SUBMISSIONSPACE,LIGHT & VENTILATION
  • Page 9UBBL SPACE,LIGHT & VENTILATION
  • Page 1002 ASSIGNMENT 2
  • QUESTION 1QUESTION 1 INTERIOR DESIGN LICENSURE EXAMINATION
  • QUESTION 1QUESTION 1B QUESTION 1A
  • QUESTION 2QUESTION 2 (30 marks)
  • QUESTION 2QUESTION 28 QUESTION 2A
  • Page 1503 ASSIGNMENT 3
  • SIZE: 893SQFTRENTAL: RM3600/MONTH RENT RATE: RM 4.14 PSF (FLOOR)
  • SERVICE FRAMEWORKMARKETINGS STRATEGIES SPATIAL PLANNING & DESIGN CONSULTANCY (01
  • FUTURE PRACTICEDIGITAL & SMART DESIGN PRACTICE D
  • DRAFT SUBMISSIONSTAMPING MONTHLY EXPENDITURE
  • Page 2104 FINAL ASSIGNMENT
  • LIOW CHUN GUAN 0351029PROFESSIONAL PPRACTICE ARC 62604 FINAL PROJECT
  • SEVENTH SCHEDULE: MAXIMUM TRAVEL DISTANCEMEASUREMENT OF TRAVI UBBL 140(3G) THE MAXIMUM TRAVEL DISTANCES SHALL BE AS SPECIFIED IN THE SEV EXITS TO BE ACCESSIBLE AT ALL TIMES
  • EL DISTANCE TO EXITSTO EXITS AND DEAD END LIMITS ENTH SCHEDULE OF THESE BY LAWS EXIT ROUTE
  • DISABLED ACCESSIBILITYEXTINGUISHING SYSTEM FIRE ALARM
  • DRAFT SUBMISSIONDESIGN PROJECT ECHOES SACRED ECHOES IS AN IMMERSIVE CULTURAL EXPERIENCE CENTRE INSPIRED BY THE NINE EMPEROR GODS FESTIVAL AND THE PHILOSOPHY OF YIN AND YANG LOCATED IN ROYAL KLANG TOWN, THE PROJECT AIMS TO PRESERVE AND REINTERPRET LOCAL CULTURAL HERITAGE THROUGH INTERACTIVE EXHIBITIONS RITUAL-INSPIRED SPATIAL EXPERIENCES, TRADITIONAL CRAFT WORKSHOPS LEARNING SPACES AND COMMUNITY GATHERING AREAS. THE DESIGN CREATES A CONTEMPORARY PLATFORM FOR CULTURAL EDUCATION ENGAGEMENT AND CONTION WHILE STRENGTHENING APPRECIATION BETWE TRADITION
  • Page 2705 CONCLUSION
  • REFLECTIVE ESSAYTHIS PROFESSIONAL PRACTICE MODULE HAS PROVIDED ME WITH A DEEPER UNDERSTANDING OF THE RESPONSIBILITIES AND REALITIES OF BECOMING A PROFESSIONAL INTERIOR DESIGNER. THROUGHOUT THE SEMESTER, I GAINED VALUABLE KNOWLEDGE BEYOND THE DESIGN PROCESS, INCLUDING BUILDING BY-LAWS, PROFESSIONAL ETHICS, LICENSING REQUIREMENTS, CONSULTANCY PRACTICE, BUSINESS MANAGEMENT, AND STATUTORY SUBMISSION PROCEDURES. EACH ASSIGNMENT CHALLENGED ME TO THINK CRITICALLY, CONDUCT THOROUGH RESEARCH, AND APPLY INDUSTRY STANDARDS IN A PRACTICAL CONTEXT. WORKING ON THESE PROJECTS HAS STRENGTHENED MY ABILITY TO CONNECT CREATIVE DESIGN WITH PROFESSIONAL PRACTICE. I REALISED THAT SUCCESSFUL INTERIOR DESIGN IS NOT ONLY ABOUT CREATING
  • Page 2906 E-PORTFOLIO LINK
Text of this page

DISABLED ACCESSIBILITY

  • EXTINGUISHING SYSTEM
  • FIRE ALARM
  • OCCUPANCY HAZARD
  • FLOOR LEVEL

WAYFINDING, GUIDED PATH AND OTHER

PHYSICAL SUPPORT OF INFORMATION TACTILE FLOOR COVERINGS OR A RUNNER AS WELL AS TACTILE WALKING SURFACE INDICATOR (TWS) CAN HELP IN LOCATING ENTRANCE DOORS, COUNTERS ETC.

2- Manual electric fire alarm system 4 - Public address system

5 - Fireman intercom system and fire command centre

6- Automatic fire monitoring system

3. Two storeys and above (total floor

MS1184 (7.2)

A-Automatic Sprinkler System G-Hose Reel System area)

  • (d) Exceeding 3,000 sqm
  • CURATED RETAIL GALLERY
  • BLESSING COURT
  • FLOOR & WALL SURFACES

FLOOR FINISHES SHOULD HAVE NON-SLIP SURFACE WITH A TEXTURE TRAVERSABLE BY DISABLED PERSONS.

MS1184 (7.29)

VII PLACE OF ASSEMBLY

2. Convention centre, community centre, private club, exhibition centre, museum or art gallery (total floor area) (c) Exceeding 2,000 square metres

WIDTH OF THE PATH

MS1184 THE UNOBSTRUCTED WIDTH OF THE PATH SHALL BE NOT LESS THAN 1800 MM FOR CONSTANT TWO-WAY TRAFFIC.

  • MATERIAL SELECTION
  • INSLX
  • FIRE RETARDANT PAINT
  • HEIGHT

• COUNTER HEIGHT: 740-800 MM FROM FLOOR. CLEAR KNEE SPACE: MINIMUM 700 MM.

RECEPTION DESKS SHOULD ALLOW FRONT WHEELCHAIR ACCESS.

PART OF THE DESK SHOULD BE HIGHER (950-1100 MM) FOR STANDING USERS.

  • MS1184
  • FIRE RATED GLASS
  • MOSAIC TILES
  • FIRE RATED WOOD
  • CONCRETE
  • FIRE RETARDANT
  • PAINT

BUILDING REQUIREMENTS FOR DISABLED PERSONS

⚫ BUILDINGS MUST PROVIDE PWD ACCESS TO ENTER, EXIT, AND MOVE WITHIN, EXCEPT IN AREAS USED ONLY FOR MAINTENANCE OR INSPECTION.

⚫ MUST INCLUDE PWD-FRIENDLY FACILITIES, COMPLYING WITH MS 1183 & MS 1184.

UBBL 34A

MATERIAL MANUFACTURE & INGREDIENTS USAGE OF CERTIFIED ECO-FRIENDLY BUILDING INTERIOR MATERIALS FROM MANUFACTURERS COMMITTED RESPONSIBLE SOURCING AND MINIMAL CHEMICALS. (USE ≥5, USE ≥10 DIFFERENT.)

MATERIAL REUSE & SELECTION

MR1

INTERIOR MATERIALS MAKE UP ≥10% OF FIT-OUT COSTS. NON-STRUCTURAL MATERIAL COMPRISE ≥25% OF FIT-OUT COSTS.

  • +2PT
  • MR5
  • TO +2PT
  • REGIONAL MATERIALS
  • MR3

USE LOCALLY SOURCED INTERIOR MATERIALS FOR ≥50% OF FIT-OUT COST.

  • CIRCULATION SPACE
  • +1PT
  • RECYCLED CONTENT MATERIALS

PROMOTE MATERIALS WITH RECYCLED CONTENT IN BUILDING INTERIOR ≥30% PRODUCTS WITH RECYCLED CONTENT (FLOOR/CEILING/WALL/FIT-OFF).

⚫ MANOEUVRING SPACE IN FRONT OF DOORS: MINIMUM 1500 MM X 1500 MM.

FOR 180° WHEELCHAIR TURN: MINIMUM 1600 MM × 2150 MM.

  • MR2 +4PT
  • MS1184 (10.7)
  • FIRE RESISTANCE

UBBL

EACH STRUCTURAL ELEMENT MUST BE CONSTRUCTED TO ACHIEVE THE FIRE RESISTANCE DURATION SPECIFIED IN THE NINTH SCHEDULE.

MATERIAL FOR CONSTRUCTION

A BUILDING PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM SHALL USE FIRE-RATED GLASS.

UBBL

WC COMPARTMENTS FOR AMBULANT DISABLED PEOPLE

WC COMPARTMENTS FOR AMBULANT DISABLED USERS MUST HAVE:

TOILET SEAT HEIGHT, DEPTH, AND WALL DISTANCE AS PER CLAUSE 25.6. CLEAR SPACE IN FRONT: MINIMUM 900 MM × 900 MM.

OUTWARD OPENING DOOR, MINIMUM WIDTH 800 MM (ESPECIALLY IN ELDERLY OR MEDICAL SETTINGS).

MS1184 (25.2

GRAB RAILS ON BOTH SIDES.

INDEPENDENT WATER SUPPLY AND FLOOR DRAIN WHERE REQUIRED.

HANDWASHING MUST BE COMMUNAL (IN SHARED WASHROOMS) OR PROVIDED NEARBY (IN STANDALONE UNITS).

SPRINKLER SYSTEM

NOT MORE THAN 4 M APART FROM EACH OTHER (REF: GUIDE TO FIRE PROTECTION IN MALAYSIA 11.2.7 SPRINKLER HEADS).

HOSE REEL SYSTEM COMPLY WITH MS 1447, PLACED WITHIN 30 M HOSE COVERAGE EACH HOSE REEL (REF: GUIDE TO FIRE PROTECTION IN MALAYSIA 7.7.2 HOSE REELS).

FLOOR & WALL SURFACES

WASHROOM

• RAMPS OFFER ACCESSIBLE ROUTES BETWEEN LEVEL CHANGES WITHOUT MECHANICAL DEVICES.

TACTILE WARNING INDICATORS MUST BE PLACED AT THE TOP AND BOTTOM OF RAMPS ON ACCESSIBLE PATHS.

  • MS1184 (8)
  • D6
  • LEGENDS
  • HIGH FREQUENCY BALLASTS
  • EQ9

INSTALL HIGH FREQUENCY BALLASTS IN FLUORESCENT LUMINAIRES FOR 100% OF INTERIOR SPACES.

  • +1PT
  • UBBL - UNIFORM BUILDING BY-LAW
  • SM - SUSTAINABLE PLANNING & MANAGEMENT

EQ - INDOOR ENVIRONMENTAL QUALITY WE - WATER EFFICIENCY

  • GBI - GREEN BUILDING INDEX
  • EE - ENERGRY EFFICIENCY
  • MS1184 - MALAYSIAN STANDARD 1184
  • MR - MATERIAL & RESOURCES