  • ARC 62604BACHELOR OF ARTS (HONOURS) IN INTERIOR ARCHITECTURE PROFESSIONAL
  • 01 ASSIGNMENT 1GROUP PRESENTATION SPREAD (SPACE LIGHT & VENTILATION) WEEKLY PROGRESS SUBMISSIONS
  • Page 301 ASSIGNMENT 1
  • SPACE, LIGHT & VENTILATIONBY-LAW 35 ACCESS FROM A STREET
  • BY-LAW 37PROJECTIONS OVER THE STREET AND OVER THE BUILDING LINE BY-LAW 39
  • BY-LAW 40AIR-WELLS Skylight to maximize use of natural light.
  • Page 73 This provision apply to building with mechanically ventilated or air conditioned. The provisions of these bylaws regarding natural ventilation and natural lighting shall not apply to lavatories, water closets, bathrooms, or corridors where permanent mechanical ventilation is provided for and maintained in accordance with the requirements of the Third Schedule to these bylaws.
  • DRAFT SUBMISSIONSPACE,LIGHT & VENTILATION
  • Page 9UBBL SPACE,LIGHT & VENTILATION
  • Page 1002 ASSIGNMENT 2
  • QUESTION 1QUESTION 1 INTERIOR DESIGN LICENSURE EXAMINATION
  • QUESTION 1QUESTION 1B QUESTION 1A
  • QUESTION 2QUESTION 2 (30 marks)
  • QUESTION 2QUESTION 28 QUESTION 2A
  • Page 1503 ASSIGNMENT 3
  • SIZE: 893SQFTRENTAL: RM3600/MONTH RENT RATE: RM 4.14 PSF (FLOOR)
  • SERVICE FRAMEWORKMARKETINGS STRATEGIES SPATIAL PLANNING & DESIGN CONSULTANCY (01
  • FUTURE PRACTICEDIGITAL & SMART DESIGN PRACTICE D
  • DRAFT SUBMISSIONSTAMPING MONTHLY EXPENDITURE
  • Page 2104 FINAL ASSIGNMENT
  • LIOW CHUN GUAN 0351029PROFESSIONAL PPRACTICE ARC 62604 FINAL PROJECT
  • SEVENTH SCHEDULE: MAXIMUM TRAVEL DISTANCEMEASUREMENT OF TRAVI UBBL 140(3G) THE MAXIMUM TRAVEL DISTANCES SHALL BE AS SPECIFIED IN THE SEV EXITS TO BE ACCESSIBLE AT ALL TIMES
  • EL DISTANCE TO EXITSTO EXITS AND DEAD END LIMITS ENTH SCHEDULE OF THESE BY LAWS EXIT ROUTE
  • DISABLED ACCESSIBILITYEXTINGUISHING SYSTEM FIRE ALARM
  • DRAFT SUBMISSIONDESIGN PROJECT ECHOES SACRED ECHOES IS AN IMMERSIVE CULTURAL EXPERIENCE CENTRE INSPIRED BY THE NINE EMPEROR GODS FESTIVAL AND THE PHILOSOPHY OF YIN AND YANG LOCATED IN ROYAL KLANG TOWN, THE PROJECT AIMS TO PRESERVE AND REINTERPRET LOCAL CULTURAL HERITAGE THROUGH INTERACTIVE EXHIBITIONS RITUAL-INSPIRED SPATIAL EXPERIENCES, TRADITIONAL CRAFT WORKSHOPS LEARNING SPACES AND COMMUNITY GATHERING AREAS. THE DESIGN CREATES A CONTEMPORARY PLATFORM FOR CULTURAL EDUCATION ENGAGEMENT AND CONTION WHILE STRENGTHENING APPRECIATION BETWE TRADITION
  • Page 2705 CONCLUSION
  • REFLECTIVE ESSAYTHIS PROFESSIONAL PRACTICE MODULE HAS PROVIDED ME WITH A DEEPER UNDERSTANDING OF THE RESPONSIBILITIES AND REALITIES OF BECOMING A PROFESSIONAL INTERIOR DESIGNER. THROUGHOUT THE SEMESTER, I GAINED VALUABLE KNOWLEDGE BEYOND THE DESIGN PROCESS, INCLUDING BUILDING BY-LAWS, PROFESSIONAL ETHICS, LICENSING REQUIREMENTS, CONSULTANCY PRACTICE, BUSINESS MANAGEMENT, AND STATUTORY SUBMISSION PROCEDURES. EACH ASSIGNMENT CHALLENGED ME TO THINK CRITICALLY, CONDUCT THOROUGH RESEARCH, AND APPLY INDUSTRY STANDARDS IN A PRACTICAL CONTEXT. WORKING ON THESE PROJECTS HAS STRENGTHENED MY ABILITY TO CONNECT CREATIVE DESIGN WITH PROFESSIONAL PRACTICE. I REALISED THAT SUCCESSFUL INTERIOR DESIGN IS NOT ONLY ABOUT CREATING
  • Page 2906 E-PORTFOLIO LINK
Text of this page

SPACE, LIGHT & VENTILATION

  • BY-LAW 35
  • ACCESS FROM A STREET
  • BY-LAW 34A
  • BUILDING REQUIREMENTS FOR DISABLED PERSONS.

1 Any building or part thereof to which this law applies

Every building not fronting a street must have access from a street, and the access must follow a layout plan approved by the competent planning or local authority.

shall:

(a) provide access for disabled persons to enter, exit & move within the building, except areas used wholly/mainly for inspection, maintenance or repair of the building/services/fixed plant or machinery; and (b) include facilities for use by disabled persons.

PUBLIC & COMMERCIAL BUILDINGS

BY-LAW 31

OPEN SPACES NOT TO BE ALTERED OR ROOFED.

Open spaces shall not be altered or roofed without 1 written approval from the local authority (unless the local authority is satisfied that the free movement of air will not be affected or obstructed).

  • BY-LAW 30
  • OPEN SPACES TO BE PROVIDED.
  • Site with no street frontage

U Accessible Route & Turning Space

All new buildings shall provide a dedicated open space of the required dimensions. (unless the local authority confirms that sufficient air space is permanently provided).

Stepped Access / Ambulant Stairs

ALL BUILDINGS

Any person acting in contravention shall be required to remove the alteration or roof and restore the open space.

  • Wheelchair Ramp Access
  • Approved Access Path
  • ALL BUILDINGS
  • 01500mm
  • BY-LAW 34
  • SPACE ABOUT DETACHED BUILDINGS.
  • : 275mm

Riser S150mm

1 Buildings not facing a street must have street access approved by the planning or local authority.

Pedestrian Rap Gradient: 1 in 10

BY-LAW 32

Reference Standards: MS 1184: Universal Design & Accessibility MS 1183: Fire Safety & Egress

Buildings to which this by-law applies, whether already erected, under construction, or with approved plans before commencement of this by-law, shall be modified/altered to comply within ≤3 years from the commencement date.

Notwithstanding para. (3), the local authority may, if justified: (a) grant extension(s) of time for compliance with this by-law; or (b) permit specified variations, deviations or exemptions from any provision of this by-law.

Any person aggrieved by the local authority's decision under para. (4) may appeal in writing to the State Authority within ≤30 days of receiving the decision, and the State Authority's decision shall be final.

SPACE ABOUT BUILDINGS ABUTTING A STREET AND A BACK-LANE.

(a) For residential buildings, the open space shall be 21/3 of the built-up area of the building lot. 1 (b) For non-residential buildings, the open space shall be 21/10 of the built-up area of the building lot.

For the purpose of calculating the required open space: 2 (a) In a two-storey shophouse, a single-storey annexe that is not a liveable room and does not exceed the height of the ground-floor ceiling shall be treated as neutral space and shall not be counted as open space;

RESIDENTIAL

NON-RESIDENTIAL

(b) 1/2 of the width of the back lane shall be counted as open space;

  • SHOPHOUSE
  • BY-LAW 33
  • SPACE ABOUT BUILDINGS ON LOTS ABUTTING
  • A STREET AND HAVING NO BACK-LANE.

For buildings on lots abutting a street without a back lane, the open space shall be located at the rear of the building and extend across the full width of the lot.

"Does not exceed the height of the ground-floor ceiling"

(c) Balconies, passageways, and sunshades projecting

≤1 metre may be counted as open space;

Where open space is not adjacent to a back lane, it shall 3 be located at the rear of the building, extend across the full width of the lot, and have a minimum clear width of 22.5 metres (excluding projections such as awnings, sunshades, or balconies).

(d) Open space between the street and the setback line of a terrace house shall not be counted as open space.

  • ALL BUILDINGS
  • ALL BUILDINGS
  • ALL BUILDINGS
  • Lot Lines Buildable Area
  • BACK-LANE
  • ≤1M
  • Rear Yard (Setback)

Extend across the full width of the lot

  • 22.5M
  • Required Yard
  • Required Yard
  • Foot Print
  • Required Yard
  • Foot Print

Foot Print Buildable AreĠ Front Lot Line Street R.O.W.

  • Side Yard (Setback)+
  • Side Yard (Setback)-
  • Side Yard (Setback)
  • Building Line
  • Buildable Ared
  • Building Line
  • Building Line
  • Front Yard (Setback)
  • Front Yard (Setback)]
  • Front Yard (Setback)]
  • Front Lot Line Street R.O.W.
  • Front Lot Line Street R.O.W.
  • ALL BUILDINGS
  • STREET
  • STREET
  • STREET